When you hear about the 1-inch dc24v solenoid valve, the first thing that comes to mind is a regular shut-off valve. But in practice, the difference between “it just works” and “it works correctly” is colossal. Many people think that the main thing is the 24V voltage and the inch thread, and the rest is trifles. These are the kinds of attitudes we at Shandong Linyao Intelligent Agriculture Technology LLC constantly encounter, especially when clients try to save on “unimportant” parts.
Let's take the standardsolenoid valve 1 inch dc24vfor drip irrigation systems. It would seem, what could go wrong there? But if you don’t pay attention to the body material, you’ll get corrosion within a season. In our projects, for example for smart greenhouses, we use brass or stainless steel, even if the customer asks for “cheaper”. Experience has shown that saving on material backfires when the valve jams at the most inopportune moment.
Another point is the type of seals. NBR or EPDM? For water with fertilizers, EPDM is better; it is more resistant to chemicals. But some manufacturers save money, install NBR - and after six months the seals swell. Once we had to redo an entire system at a vegetable farm near Voronezh precisely because of this.
But aboutdc24vMany people forget that not only voltage stability is important, but also protection against surges. We always install stabilizers, especially in the field. I once saw how a whole group of valves burned out due to a thunderstorm - the repair cost more than the entire protection system.
The most common mistake is installing without a filter. Even in clean water there are suspended matter that clog the channel. We recommend placing a 100+ micron filter in front of eachsolenoid valve. Tested: this increases service life by 40-50%.
Another point is orientation during installation. Some technicians install it as necessary, and then wonder why the valve is noisy or does not close well. In a vertical position with the coil up - we always tell the installers, but not everyone listens.
Connecting the wires is a separate matter. Terminal blocks must be protected from moisture, even if the valve is IP65. I have seen cases where, in field conditions, contacts oxidized within a couple of months. Now we always use sealed connectors or at least heat shrink with silicone sealant.
In our smart agriculture projectssolenoid valve 1 inchrarely works autonomously. This is usually part of a distributed network with controllers. Protocol coordination is important here - Modbus RTU, Profibus or simple discrete signals. For small farms we recommend simple solutions, without a complex data bus.
There was an interesting case in Tatarstan: a customer wanted to control valves via GSM. It would seem a standard task. But it turned out that there was poor communication in the area - the commands arrived with a delay of up to a minute. I had to install local controllers with automatic watering by timer as a backup option.
We are now testing valves with feedback in an experimental farm near Kazan - so that we can see not only the received command, but also the real state. It’s still a little expensive, but for precision crops such as salads or berries, it’s worth it.
Maintainability is something that is often forgotten. goodsolenoid valve dc24vmust be disassembled without special tools. We at Shandong Linyao Intelligent Agriculture Technology LLC have even developed our own quick diagnostic method: we check the coil resistance with a multimeter (should be 35-40 Ohms for 24V), then call it to see if it works.
Winter preservation is a separate issue. If water remains in the system, the valves are guaranteed to fail. Every year in the fall we carry out blowing with a compressor, but some farms skimp on this... In the spring they get torn housings.
Spare parts - we keep the most vulnerable components in stock: coils, plungers, springs. Experience has shown that it is faster and cheaper to replace a coil than the entire valve. Although some people prefer to 'throw it away and install a new one' - this is not our approach.
When we calculate the cost of ownership, we look not only at the price of the valve. Cheapsolenoid valve 1 inchmay require replacement in a year, or even earlier. Expensive - work for 5-7 years. We usually recommend the middle segment, proven manufacturers. I won’t name brands, but those supplied through official distributors perform better than “no names”.
Energy consumption is another hidden cost factor. Modern valves consume 2-3 W in pulse mode, older models consume up to 8 W continuously. For large farms with hundreds of valves, the difference in electricity bills reaches tens of thousands of rubles per year.
Delivery times are critical during the season. It happened that we waited for valves for 2-3 months while the system was idle. Now we work with reliable suppliers who keep stock in warehouses in Russia. For example, through our website https://www.lyzhihuinongye.ru - there is always the possibility of quick reservations.
Now I see a trend towards 'smart' valves with flow sensors. This allows you not only to open/close, but also to control the actual water flow. For precision farming it is invaluable. We are already testing such solutions in our projects.
Another direction is reducing hydraulic resistance. Modern designs minimize pressure loss, which is especially important for long irrigation lines. Sometimes a difference of 0.1 atm decides whether the water will reach the end of the row or not.
Biostable materials are important for organic farming. Some farms are refusing plastics with additives and are demanding 'clean' materials. We have to look for a compromise between durability and environmental friendliness.
Overall,solenoid valve 1 inch dc24v- not just an 'electric faucet', but a complex engineering product, the selection and installation of which determines the efficiency of the entire irrigation system. And as our practice at Shandong Linyao Intelligent Agriculture Technology LLC shows, there are no trifles here.